Add explicit "no protection device" state for circuits

Circuits can now record that they deliberately have no protection device
(type NONE, shown as "–"), separate from circuits whose protection is
still open. Migration 0017 makes rated_current_a nullable.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
Julian Appel 2026-10-30 13:11:28 +01:00
parent 1f3b903809
commit 38019fe087
27 changed files with 3673 additions and 132 deletions

View file

@ -7,6 +7,7 @@ import type {
import type {
BreakerTripCharacteristic,
FuseUtilizationCategory,
NoCircuitProtectionDeviceType,
ProtectionDeviceType,
RcdType,
} from "../shared/constants/protection-device";
@ -517,6 +518,16 @@ export interface CircuitTreeProtectionDeviceDto {
ratedResidualCurrentMa?: number;
}
// Explicit "no protection device" on a circuit; shown as "–". A circuit
// without protectionDevice is still open for planning.
export interface CircuitTreeNoProtectionDeviceDto {
type: NoCircuitProtectionDeviceType;
}
export type CircuitTreeCircuitProtectionDeviceDto =
| CircuitTreeProtectionDeviceDto
| CircuitTreeNoProtectionDeviceDto;
export interface CircuitTreeComponentDto {
id: string;
circuitListId: string;
@ -551,7 +562,7 @@ export interface CircuitTreeCircuitDto {
circuitCosPhi: number;
deviceRows: CircuitTreeDeviceRowDto[];
downstreamBoardLoads: CircuitTreeDownstreamBoardLoadDto[];
protectionDevice?: CircuitTreeProtectionDeviceDto;
protectionDevice?: CircuitTreeCircuitProtectionDeviceDto;
}
export interface CircuitTreeSectionDto {