forked from jappel/leistungsbilanz-ts
Add per-project socket limit and Revit socket device-type flag
- Project setting maxSocketsPerCircuit (migration 0018, project.update-settings schema 4, snapshot schema 11); older command and snapshot versions keep or upgrade the value to null. - Revit configuration schema 2 marks device types as socket; version 1 stays readable and derives the flag from socketCount family rules. - Settings dialog field and device-type card on the Revit page. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
parent
85cbdbf8e0
commit
e48042bde3
35 changed files with 3781 additions and 41 deletions
|
|
@ -12,7 +12,7 @@ const deviceTypeA = "10000000-0000-4000-8000-000000000001";
|
|||
const deviceTypeB = "10000000-0000-4000-8000-000000000002";
|
||||
const newWorksharingId = "AAAAAAAA-BBBB-CCCC-DDDD-EEEEEEEEEEEE-00000003";
|
||||
const catalogs = { floors: [], rooms: [], distributionBoards: [], projectDevices: [] };
|
||||
const configuration = { ...createDefaultExternalModelConfiguration(), ...externalXlsxTestConfiguration, deviceTypes: [{ id: deviceTypeA, name: "Steckdose", category: "single_phase" as const, defaults: { powerPerUnitW: null, simultaneityFactor: 1, cosPhi: 0.9, costGroup: null } }, { id: deviceTypeB, name: "Leuchte", category: "lighting" as const, defaults: { powerPerUnitW: 40, simultaneityFactor: 1, cosPhi: null, costGroup: null } }], familyTypeRules: [{ id: "20000000-0000-4000-8000-000000000001", exactFamilyAndType: "Steckdose: Standard", deviceTypeId: deviceTypeA, quantityRule: "socketCount" as const }, { id: "20000000-0000-4000-8000-000000000002", exactFamilyAndType: "Leuchte: Decke", deviceTypeId: deviceTypeB, quantityRule: "one" as const }] };
|
||||
const configuration = { ...createDefaultExternalModelConfiguration(), ...externalXlsxTestConfiguration, deviceTypes: [{ id: deviceTypeA, name: "Steckdose", category: "single_phase" as const, defaults: { powerPerUnitW: null, simultaneityFactor: 1, cosPhi: 0.9, costGroup: null }, isSocket: true }, { id: deviceTypeB, name: "Leuchte", category: "lighting" as const, defaults: { powerPerUnitW: 40, simultaneityFactor: 1, cosPhi: null, costGroup: null }, isSocket: false }], familyTypeRules: [{ id: "20000000-0000-4000-8000-000000000001", exactFamilyAndType: "Steckdose: Standard", deviceTypeId: deviceTypeA, quantityRule: "socketCount" as const }, { id: "20000000-0000-4000-8000-000000000002", exactFamilyAndType: "Leuchte: Decke", deviceTypeId: deviceTypeB, quantityRule: "one" as const }] };
|
||||
|
||||
async function initialState() {
|
||||
const bytes = await createRevitXlsxFixture();
|
||||
|
|
|
|||
Loading…
Add table
Add a link
Reference in a new issue