Commit graph

123 commits

Author SHA1 Message Date
38019fe087 Add explicit "no protection device" state for circuits
Circuits can now record that they deliberately have no protection device
(type NONE, shown as "–"), separate from circuits whose protection is
still open. Migration 0017 makes rated_current_a nullable.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-30 13:11:28 +01:00
d0bd4fe7e0 Export and import single distribution boards as JSON
A board with its complete circuit list can be downloaded as a
leistungsbilanz.distribution-board file and imported into any project as
a new board. The import reuses distribution-board.insert-subtree, so it
is one revision with restart-safe Undo/Redo. All ids are new;
project-bound references (project devices with override metadata, room
ids, floor, logical feed, a disabled supply type and the Revit quantity
share) are dropped, circuit voltages follow the target project, and the
response lists these adjustments. The project page offers export per
board and import in the board card header.

Refs #26

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-30 07:38:28 +01:00
17a3945813 Add cell copy/paste, multi-row edits and a context menu to the circuit grid
Ctrl+C/Ctrl+V copy and paste grid cells without opening an editor, using
the document copy/paste events so it also works over plain HTTP in the
LAN. Protection and cable summaries copy the complete circuit record;
tab-separated blocks from Excel spread over visible rows and columns.
With a Ctrl/Shift multi-selection, typing, pasting and the protection
dialog apply to every selected row that can take the value, including
device power and GZF; other cells are skipped and reported.

All of these writes use the new circuit-list.bulk-update command. It
carries complete circuit.update, circuit-device-row.update and
circuit-protection.update commands, applies them with the single-command
rules in one transaction and stores the reversed inverses, so each edit
is one undo step. The single-command apply logic is extracted for reuse.

A right-click menu (also context-menu key / Shift+F10) offers copy,
paste, edit, protection, cable sizing, insert circuit below, add device
and delete. The protection summary is now selected by click and opened
by double click, Enter or F2. Existing numbers open in the inline editor
with a decimal comma, so confirming an unchanged decimal no longer fails.

Refs #26

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-30 07:38:28 +01:00
01312b89fe Keep single-device circuit names equal to their device row
A circuit with exactly one device row and no fed distribution board is
shown as that row, so its own name was hidden and could drift (e.g.
"Neuer Stromkreis" in the print view). Commands that create or leave
such a circuit, rename its row or unlink its downstream board now set
the circuit name to the row name and store the change as optional
circuitDisplayNames, so Undo restores an overwritten free name exactly.
Migration 0016 aligns existing data.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-29 13:56:02 +01:00
2581beee3c Add Linear XLSX follow-up import 2026-09-30 20:40:40 +02:00
77d775fde1 Complete Revit object editor assignments 2026-09-30 14:35:14 +02:00
4ac32e103d Add virtualized Revit object planning 2026-09-30 10:03:36 +02:00
bfdd048269 Add Linear XLSX initial import 2026-09-30 09:50:58 +02:00
1cfeb06ec7 Replace Revit CSV backend with Linear XLSX 2026-09-30 08:46:07 +02:00
847f4e9493 Harden user management integration 2026-09-28 22:42:03 +02:00
73579d1e79 Merge branch 'main' into feature/user-management 2026-09-28 22:32:48 +02:00
ade21fe386 Create feeder circuits while linking boards 2026-09-28 22:14:30 +02:00
Grovy311
728132e52a Warn at startup when no user exists and no bootstrap admin is configured
Also document that Sec-Fetch-Site is only sent over HTTPS, so plain-HTTP
LAN access relies on SameSite=Lax alone.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 21:47:30 +02:00
Grovy311
95bfba2f67 Merge origin/main into feature/user-management
Renumber the users migration to 0013_users so it follows the upstream
0012_good_gateway (logical board feeds); AGENTS.md deferred-work list keeps
both the new feed items and the auth items.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 21:46:21 +02:00
Grovy311
5073d9342a Harden authentication and put filter toggle and fields in one row
Security: per-username login throttling, constant-time unknown-user check,
Sec-Fetch-Site CSRF guard for writes, session rotation on login and
password change, absolute session lifetime, sessions ended on reset and
deactivation, last-admin protection, input length caps, ASCII usernames,
clickjacking headers. Covered by tests/authentication.test.ts.

Filter panel: toggle, fields and count share one row to save space.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 21:30:30 +02:00
Grovy311
c56cfb30ad Add login-required user management (admin/user roles, Config->Benutzer)
No self-signup: admins create every account in Config -> Benutzer with a
typed start password; a forced password change gates first use. Session-
cookie auth protects all /api/* routes; /api/users additionally requires
the admin role. See docs/authentication.md.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-28 19:51:47 +02:00
042a050876 Show logical feeder loads in project and circuit views 2026-09-27 22:37:04 +02:00
dfeb0e3cb6 Add recursive distribution board load projection 2026-09-27 22:31:56 +02:00
b893c72534 Add logical distribution board feed links 2026-09-27 22:21:58 +02:00
dce31ee143 Add optional room areas 2026-09-27 20:00:03 +02:00
573487666c Integrate rough estimate balance 2026-09-27 12:37:59 +02:00
Grovy311
37a70b6b36 Add the rough power balance module for early design phases
In LPH 2/3 there are no circuits yet, but the office needs a power
balance by DIN 276 cost group, as in the Excel template "Leistungsbilanz -
KG400": each trade enters consumers by piece or by area (W/m²) with GLF
and cos phi; the balance sums AV and SV per cost group, adds a reserve and
derives the maximum current.

The module is separate from the circuit structure: own tables
(migration 0010), own folder src/estimate-balance and an import-free
shared calculation used by API and UI. Writes go through project commands
(estimate-balance.insert/.update/.delete with complete documents), so
revision checks and Undo/Redo apply; it is not part of project snapshots
or transfer yet. A comparison endpoint sums the device rows of all circuit
lists by cost group (longest prefix) against the estimate.

The UI adds a sidebar entry, a list of Stände (template KG 400, empty or
copy) and a spreadsheet-like editor with autosave, AMEV picker for the
GLF, totals, reserve, maximum current, comparison table and print layout.
The tests reproduce the template example exactly (143.24 kW, 148.48 kVA,
157.56 kW / 163.33 kVA with 10 % reserve, 235.75 A). See
docs/estimate-balance.md and issue #7.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 17:39:28 +02:00
Grovy311
cd89c4a499 Add buildings above floors and a building structure page
Projects with several buildings could not be structured: floors and rooms
hung directly off the project. Floors can now belong to a building
(migration 0009: table buildings, nullable floors.building_id). Rooms and
distribution boards keep their floor; their building follows from it.
Existing floors stay without a building.

Buildings use the location-structure command store with
project-building.insert/.update/.delete, inverses and persistent Undo/Redo;
deleting a building with assigned floors is rejected. Floor commands carry
buildingId since command version 2. Version 1 floor commands from existing
history predate buildings and are upgraded with buildingId = null before
they are executed and persisted, so forward and inverse keep one version.

Project snapshot schema 7 stores buildings and floor.buildingId; versions
1-6 are upgraded without buildings. Restore and portable transfer include
buildings, and the transfer remaps building ids.

Buildings, floors and rooms move from the project overview to their own
page /projects/:id/struktur with three columns (Gebäude -> Etagen -> Räume)
that filter each other, and a sidebar entry. Floor selects in the board and
room dialogs are grouped by building. Unchanged dialogs close without a
command. Details in docs/building-structure.md; see issue #6.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 12:52:34 +02:00
Grovy311
7692699ee2 Add print cover fields and office profile
- Project settings gain siteAddress, workStage, projectLead and
  projectEditor (project.update-settings schema version 3, migration 0009);
  versions 2 and 1 stay executable and keep the current cover values.
  Snapshot schema 6 carries the fields; older versions upgrade with null.
- Global office profile (office name/address) next to the document logo:
  table document_branding_settings, PUT /api/document-branding/office,
  editable from the print view toolbar.
- Cover page reads all fields; empty values show the "[ergänzen]" marker.
  The Planstände editor column shows the project editor.
- Shared logo constants moved to a dependency-free module so the Next.js
  bundler can import them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 10:39:18 +02:00
Grovy311
4779e4a1a7 Add print view, board info card and document logo upload
- Seitenansicht (/projects/:projectId/print): tabular cover page, board
  overview with supply structure and power sums, one plan per board with a
  repeating title block; PDF via the browser print dialog with named @page
  rules (A4 portrait cover, A4/A3 landscape plans, page x of y).
- Distribution-board info card (board number, location, fed-from, remark)
  in the board edit dialog, persisted through the additively extended
  distribution-board.update command (migration 0008, snapshot schema 6,
  legacy subtree commands normalized).
- Global document logo upload (PNG/JPEG/SVG, max 2 MB) outside project
  revisions and snapshots.
- fed-from stays free text; the overview hierarchy and cumulated sums are
  preliminary until the feed link is modeled.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 10:38:59 +02:00
b45dc5002d Fix code-review findings across domain, persistence, server and frontend
Full-codebase review turned up five real correctness/security bugs and
a dozen smaller inconsistencies; all are fixed here with matching test
coverage:

- BMK uniqueness silently allowed German-umlaut duplicates ("Ä1" vs
  "ä1") because the DB's normalized index only folds ASCII case. Added
  a shared Unicode-aware pre-check used by every circuit/component
  insert and rename path (one of which had no pre-check at all).
- CircuitDeviceRow.simultaneityFactor had no upper bound at the row
  level (command model and snapshot/restore schema), unlike every
  sibling entity, letting a bad value silently corrupt power totals.
- Grid cell editing silently misread German thousands-separator input
  ("1.500" parsed as 1.5); "." is now rejected outright with a clear
  message instead of guessing.
- The editor's shared command runner (runCommand/applyHistory) had no
  re-entrancy guard, so a double click/drop could fire the same
  command twice and race a BMK collision or revision conflict. Added a
  synchronous ref guard plus isSaving on the buttons that lacked it.
- GET .../next-identifier leaked circuit-numbering state for sections
  in other projects (no ownership check, 400 instead of 404). Moved
  under /projects/:projectId and scoped it.

Also: added the missing circuits.section_id / circuit_device_rows.
circuit_id indexes (migration 0006), gave FormModal a focus trap /
Escape-to-close / focus restore and rebuilt ProjectSettingsModal on
top of it instead of duplicated markup, removed dead code (3 orphaned
domain model files, an unused persistence helper, a wrapper only used
by its own test), pointed the project page at GET /projects/:id
instead of listing+filtering client-side, closed the gap between the
documented 18 MB CSV limit and the ~17.17 MiB actually enforced, added
missing upper bounds on several free-text fields, filled in nine
missing German labels in the revision timeline, replaced a
key-order-fragile JSON.stringify equality check with a real field
comparison, made an implicit sort-order assumption in three
renumbering helpers explicit, cleared the sidebar's target selection
when it no longer resolves after a tree reload, and fixed
updateGlobalDevice to check-then-write instead of write-then-check.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-08-06 21:31:16 +02:00
a69b7b603f Add external object new circuit command 2026-08-02 18:55:57 +02:00
347b3717c3 Add external object new row command 2026-08-02 18:44:46 +02:00
1a7dd7fe03 Add external object row assignment command 2026-08-02 18:38:38 +02:00
dac19b093c Add external row quantity foundation 2026-08-02 18:26:22 +02:00
c634570018 Add atomic Revit initial import 2026-08-02 17:33:32 +02:00
e87a3289fa Include external models in project snapshots 2026-08-02 17:25:25 +02:00
76493b573e Add external model persistence foundation 2026-08-02 17:18:24 +02:00
caa6caf99f Add Revit CSV preview API 2026-08-02 16:49:42 +02:00
219da5ec3b Persist Revit CSV configuration 2026-08-02 16:33:18 +02:00
44b6fde940 Add public building project setting 2026-07-31 17:41:30 +02:00
1eed19ef6b Add editable project floors and rooms 2026-07-31 14:46:06 +02:00
1e3c721cfa Derive project device phases from category 2026-07-31 14:37:45 +02:00
734a2bcfc4 Create clean release database baseline 2026-07-31 14:07:26 +02:00
0fd564a930 Persist complete distribution board subtrees 2026-07-31 11:57:10 +02:00
13693f64b1 Model complete distribution board subtrees 2026-07-31 11:51:46 +02:00
8898117ed4 Configure circuit protection 2026-07-31 07:45:48 +02:00
18ca5eb3d4 Persist circuit protection updates 2026-07-31 07:37:38 +02:00
7a9530a914 Expose protected tree structure 2026-07-30 20:14:45 +02:00
99bdf6491b Persist populated group deletion 2026-07-30 20:10:10 +02:00
db4c757018 Define circuit group subtrees 2026-07-30 20:06:09 +02:00
3399fcd88b Persist circuit group moves 2026-07-30 20:03:11 +02:00
9ad91887b2 Plan circuit group moves 2026-07-30 19:58:45 +02:00
07925b2fd9 Persist circuit group renumbering 2026-07-30 19:56:59 +02:00
63650a623c Plan circuit group renumbering 2026-07-30 19:51:44 +02:00