Use lightweight READ_STATUS instead of full CONFIG_READ for profile polling
Live-Sync polls read_active_profile() every 1.5s, but it was requesting
a full 740-byte config dump (~124 chunk packets) just to read one
byte out of it. The firmware handles CONFIG_READ synchronously and
blocking, which delayed its LED animation update enough to make
Pulse/Blink visibly stutter on every poll cycle -- see
VersaMCU's doc/07_serial_protocol.md ("READ_STATUS vs. CONFIG_READ
fuer Polling") for the root-cause writeup on the firmware side.
read_active_profile() now sends VersaMCU's new CMD_READ_STATUS (0x06)
and reads back a single EVT_STATUS (0x86) packet instead of driving
the chunked dump protocol. Requires the corresponding firmware update
(VersaMCU commit "Add lightweight READ_STATUS command..."); older
firmware without it just times out gracefully (last_error stays
"timeout", no crash).
desktop_viewer.py's SERIAL_POLL_S/SERIAL_IDLE_S already sit back at
their original 1.5s/3.0s (temporarily raised to 8s as a stopgap before
the firmware fix landed) since the expensive dump is gone now.
Verified end-to-end against a freshly flashed board: correct profile
returned, no more visible LED stutter with Live-Sync on.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
This commit is contained in:
parent
553ecc54d8
commit
4215323f3f
1 changed files with 32 additions and 7 deletions
|
|
@ -37,6 +37,7 @@ CONFIG_SIZE = 740
|
|||
MACRO_SIZE = 512
|
||||
ACTIVE_PROFILE_OFFSET = 7
|
||||
|
||||
CMD_READ_STATUS = 0x06
|
||||
CMD_CONFIG_BEGIN = 0x10
|
||||
CMD_CONFIG_DATA = 0x11
|
||||
CMD_CONFIG_COMMIT = 0x12
|
||||
|
|
@ -46,6 +47,7 @@ CMD_MACRO_DATA = 0x21
|
|||
CMD_MACRO_COMMIT = 0x22
|
||||
CMD_MACRO_READ = 0x23
|
||||
|
||||
EVT_STATUS = 0x86
|
||||
EVT_CONFIG_ACK = 0x90
|
||||
EVT_CONFIG_NACK = 0x91
|
||||
EVT_CONFIG_BEGIN = 0x92
|
||||
|
|
@ -187,16 +189,39 @@ class VersaPadLink:
|
|||
|
||||
# ── Oeffentliche API ────────────────────────────────────────
|
||||
|
||||
def read_active_profile(self):
|
||||
"""0-2 bei Erfolg, None bei Timeout/Fehler/kein Board."""
|
||||
buf = self._read_dump(CMD_CONFIG_READ, EVT_CONFIG_BEGIN, EVT_CONFIG_DATA, EVT_CONFIG_END, CONFIG_SIZE)
|
||||
if buf is None:
|
||||
def read_active_profile(self, deadline_s=1.0):
|
||||
"""0-2 bei Erfolg, None bei Timeout/Fehler/kein Board.
|
||||
|
||||
Nutzt CMD_READ_STATUS (1 Antwortpaket) statt eines vollen CONFIG_READ-
|
||||
Dumps (124 Pakete) -- der volle Dump blockiert die Firmware lange genug,
|
||||
dass laufende LED-Pulse-Animationen beim Live-Sync-Polling sichtbar
|
||||
stottern (siehe VersaMCU doc/07_serial_protocol.md, "READ_STATUS vs.
|
||||
CONFIG_READ fuer Polling"). Für ältere Firmware ohne CMD_READ_STATUS
|
||||
faellt das Board auf keine Antwort zurueck -> Timeout, kein Absturz."""
|
||||
if not self._ensure_open():
|
||||
return None
|
||||
profile = buf[ACTIVE_PROFILE_OFFSET]
|
||||
if profile not in (0, 1, 2):
|
||||
try:
|
||||
self.ser.reset_input_buffer()
|
||||
self.ser.write(bytes([CMD_READ_STATUS, 0, 0, 0, 0, 0, 0, 0]))
|
||||
|
||||
deadline = time.time() + deadline_s
|
||||
while time.time() < deadline:
|
||||
raw = self.ser.read(PACKET_SIZE)
|
||||
if len(raw) < PACKET_SIZE:
|
||||
continue
|
||||
if raw[0] == EVT_STATUS:
|
||||
profile = raw[1]
|
||||
if profile not in (0, 1, 2):
|
||||
self.last_error = "timeout"
|
||||
return None
|
||||
self.last_error = None
|
||||
return profile
|
||||
self.last_error = "timeout"
|
||||
return None
|
||||
return profile
|
||||
except serial.SerialException:
|
||||
self.close()
|
||||
self.last_error = "busy"
|
||||
return None
|
||||
|
||||
def read_full_config(self):
|
||||
"""740B Rohdaten (alle 3 Profile) oder None."""
|
||||
|
|
|
|||
Loading…