Commit graph

8 commits

Author SHA1 Message Date
5d14bdd826 Move config storage next to the install and auto-create it if missing
versapad_combined.DEFAULT_PATH was hardcoded to this one machine's OneDrive
desktop, which made the tool unusable anywhere else. versapad_data.app_dir()
now resolves to the running .exe's own folder when frozen, or the project
directory when run from source, and DEFAULT_PATH hangs off that instead.

load_or_fetch() previously raised when both the file was missing and the
board unreachable, blocking a fresh install with no config and no board
attached. It now falls back to an empty default_combined() in that case, so
the tool is immediately usable either way. desktop_viewer's
_current_profile_view() picks up the same fallback instead of re-implementing
a narrower version of it.

Also drop the hardcoded PROFILE_NAMES dict, which had drifted out of sync
with the profile_names already stored in the combined JSON -- renaming a
profile in Programmiermodus never showed up in the read-only/browser views.
server.py and desktop_viewer.py now read names from the same JSON everywhere.

versapad_data.CONFIG_PATHS (read-only interop with the official C# VersaGUI's
JSON export) is intentionally left on the OneDrive desktop -- nothing in
this codebase writes there, it's not part of this tool's own config.
2026-08-14 23:17:11 +02:00
cjjohn
540ce5b1eb Fix crash when desktop config JSON is deleted: self-heal from board
server.py and desktop_viewer.py read-only mode required the desktop
config JSONs to exist and crashed/showed "Config-Datei fehlt" if one
was deleted, even though the board already holds the config durably
in NVM. Add versapad_combined.fetch_from_board()/load_or_fetch(): a
missing combined JSON is now transparently rebuilt from the board via
serial and cached back to disk, falling back to the legacy per-profile
JSONs (or a clear error) only when the board is unreachable.
2026-08-08 17:06:53 +02:00
cjjohn
8a2a73c68d Fix Programmiermodus default-seed bug wiping other profiles
_on_toggle_editing() seeded self.combined from default_combined() on first
activation, which reads the stale per-profile JSONs for all 3 profiles
instead of the current versapad_config_all.json. Writing to board while
only editing one profile silently reverted the other two. Now prefers
loading the current combined file, falling back to defaults only if it
doesn't exist.

Also documents the READ_STATUS polling change and the jappel PR workflow
constraint in AGENTS.md.
2026-08-07 20:50:52 +02:00
cjjohn
553ecc54d8 Restructure AGENTS.md to the projekt-doku standard, audit README status
AGENTS.md now follows the mandated section structure (Project Goal,
Aktuell unterstützte Architektur, Kritische Domänenregeln,
Existing-Codebase-Regel, Implementierungsdisziplin, Naming, Deferred
Work, Dokumentation und Verifikation) instead of an organically grown
set of headings. Folds in all prior technical notes (protocol
validation, network-drive build/runtime gotchas, threading rules)
under the appropriate section, and fixes a stale "no tray icon yet"
line that no longer matched the code. README gets an explicit honest
status paragraph (what's tested, what's not: no automated tests, no
prebuilt exe download, hardcoded paths).

No docs/ tree: project has no database or persistent multi-user
service, so the full doc structure isn't warranted per the standard.
2026-08-06 16:05:36 +02:00
cjjohn
4ac29a3e5c Add custom icon and tray-minimize behavior (like VersaGUI's TrayApp)
Minimizing or closing hides the window instead of leaving a taskbar
entry; only "Beenden" in the tray right-click menu really exits. Tray
callbacks route through a queue instead of touching Tk directly from
pystray's thread (same pattern as the earlier serial-thread fix).

Also fixes the build script: PyInstaller failed on the network share
while copying Tcl/Tk tzdata (path-length issue), so building now
happens in a local temp copy instead of directly on Z:.

Adds an info button that explains the MCP server's available tools.
2026-08-05 08:30:50 +02:00
cjjohn
e456af7c19 Add MCP server so Claude (or any MCP client) can reprogram VersaPad directly
Wraps the existing protocol/serial/combined-config layers as MCP tools
(set_button_key, set_encoder_consumer, set_macro, load_from_board,
write_to_board, ...) instead of requiring hand-written JSON + manual
GUI import. Registered at user scope via `claude mcp add`.
2026-08-05 08:16:22 +02:00
cjjohn
50658107d5 Add PyInstaller packaging (--onedir) as alternative to pyw launch
Avoids the cmd.exe flash from double-clicking run_desktop.bat and
gives a proper double-click .exe like VersaGUI.exe. Must be deployed
locally (%LOCALAPPDATA%) -- Windows silently refuses to load the
_internal DLLs when the .exe sits on the Z: network share, no error
shown. build_and_deploy.ps1 handles build + local copy in one step.
2026-08-05 08:04:38 +02:00
cjjohn
6227903ebd Initial commit: VersaPad viewer + programming mode 2026-08-04 20:03:49 +02:00