Keep single-device circuit names equal to their device row
A circuit with exactly one device row and no fed distribution board is shown as that row, so its own name was hidden and could drift (e.g. "Neuer Stromkreis" in the print view). Commands that create or leave such a circuit, rename its row or unlink its downstream board now set the circuit name to the row name and store the change as optional circuitDisplayNames, so Undo restores an overwritten free name exactly. Migration 0016 aligns existing data. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
parent
58cec53713
commit
01312b89fe
21 changed files with 4330 additions and 111 deletions
|
|
@ -58,6 +58,11 @@ See `docs/current-architecture.md` for the complete module and request flow.
|
|||
- A circuit contains zero, one or multiple device rows.
|
||||
- A single-device circuit may be displayed as one compact row.
|
||||
- A multi-device circuit must be displayed with a circuit summary row and indented device rows.
|
||||
- A circuit with exactly one device row and no fed distribution board carries
|
||||
that row's name (`syncSingleDeviceCircuitDisplayNames`). Commands that create
|
||||
or leave such a circuit, rename its row or unlink its downstream board store
|
||||
the circuit-name changes as optional `circuitDisplayNames`, so Undo restores
|
||||
an overwritten free name. Migration `0016` aligned existing data.
|
||||
- Equipment identifiers belong to circuits, not to every device row.
|
||||
- Device rows inside a circuit do not have their own equipment identifiers.
|
||||
- Protection and cable data belong to the circuit, not to individual devices.
|
||||
|
|
|
|||