Add optional cable-sizing module
Per-circuit cross-section recommendation as a separate module attached to the circuit list. It never writes project data itself: "Übernehmen" applies cable type, cross-section and length through the regular circuit.update command, so revisions and Undo/Redo stay intact. - Pure domain module (src/cable-sizing) with IEC 60364-5-52:2009 Annex B tables for PVC and XLPE, copper and aluminium, methods A1, A2, B1, B2, C, D1, D2 and E. Every value was cross-checked against public reproductions; where sources differ the lower value is used (docs/cable-sizing-module.md). - Temperature and grouping between table values round to the safer value; values outside the tables return no result instead of a factor of 1. Ground methods use B.52.18 (D2) and B.52.19 A (D1). - Overload protection: circuit-breakers In <= Iz; gG fuses additionally I2 <= 1.45 Iz with I2 = 1.6/1.9/2.1 In. - Inputs prefilled from the circuit: power, phase (group or device rows), project voltage, power-weighted cos phi, length and protective device. - Opened from a "Leitungsberechnung" button in the row actions, not from a grid cell, so cable cells keep the spreadsheet behavior. - Stateless API under /api/cable-sizing; no database table or migration. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
parent
d95f0bf5c0
commit
49488f4e1b
17 changed files with 1999 additions and 4 deletions
|
|
@ -17,8 +17,12 @@
|
|||
- Persistence currently targets local SQLite; PostgreSQL is an architectural option, not an implemented runtime.
|
||||
- The global device library supports basic CRUD and copy operations, but has no
|
||||
versioning, permissions or controlled synchronization model.
|
||||
- Final electrical sizing logic is not implemented yet.
|
||||
- No full norm-compliant voltage-drop and protection-dimensioning calculation flow yet.
|
||||
- There is no automatic sizing of all circuits. The optional cable sizing
|
||||
module suggests a cross-section for one circuit on demand (IEC 60364-5-52
|
||||
Annex B tables; no short-circuit, disconnection-time or selectivity checks,
|
||||
no methods F/G, soil resistivity fixed at 2.5 K·m/W) and does not validate
|
||||
manually entered cable values. National tables (DIN VDE 0298-4) must be
|
||||
checked by the planner; see `docs/cable-sizing-module.md`.
|
||||
- Sorting is view-only until users explicitly apply sorted order.
|
||||
- Complete-circuit drag supports one circuit at a time between groups of the
|
||||
same category. Cross-category moves and multi-circuit moves across group
|
||||
|
|
|
|||