Commit graph

118 commits

Author SHA1 Message Date
Grovy311
72189d23a5 Offer supply suggestions, drop the circuit column, center cells
The Versorgung field suggests ELT and MSR (plus values already used in
the balance) through a datalist and still accepts free text. The circuit
number column is not needed in early design phases; it is removed from
the data model, the regenerated migration 0010, the editor and the
print. All cells are centered except "Verbraucher / Flächen", group
titles and total labels.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 17:56:53 +02:00
Grovy311
e06c7d91e2 Print the rough power balance in the kbp design
The print of the rough power balance was plain grey. It now follows the
kbp design of the print view: a title block with office logo, stand,
project, number, owner, address, work stage, date, editor and office;
header row in kbp blue, cost-group rows tinted with a lilac rule, bold
subtotals, the total including reserve as a blue band, colored
deviations in the comparison, Arial, exact print colors, and a footer
with project, stand and "Seite x von y" on every page.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 17:48:37 +02:00
Grovy311
37a70b6b36 Add the rough power balance module for early design phases
In LPH 2/3 there are no circuits yet, but the office needs a power
balance by DIN 276 cost group, as in the Excel template "Leistungsbilanz -
KG400": each trade enters consumers by piece or by area (W/m²) with GLF
and cos phi; the balance sums AV and SV per cost group, adds a reserve and
derives the maximum current.

The module is separate from the circuit structure: own tables
(migration 0010), own folder src/estimate-balance and an import-free
shared calculation used by API and UI. Writes go through project commands
(estimate-balance.insert/.update/.delete with complete documents), so
revision checks and Undo/Redo apply; it is not part of project snapshots
or transfer yet. A comparison endpoint sums the device rows of all circuit
lists by cost group (longest prefix) against the estimate.

The UI adds a sidebar entry, a list of Stände (template KG 400, empty or
copy) and a spreadsheet-like editor with autosave, AMEV picker for the
GLF, totals, reserve, maximum current, comparison table and print layout.
The tests reproduce the template example exactly (143.24 kW, 148.48 kVA,
157.56 kW / 163.33 kVA with 10 % reserve, 235.75 A). See
docs/estimate-balance.md and issue #7.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 17:39:28 +02:00
Grovy311
80dbc73230 Merge fix/client-id-insecure-context for client-side ids 2026-09-26 14:22:35 +02:00
Grovy311
5f4d9bf789 Show the sidebar on every page except the print view
AppShell showed the sidebar only on the project list and overview, so it
disappeared on the building structure page and in the circuit list
editor. It is collapsible, so it now stays on every page. Only the print
view, a stand-alone document opened in its own tab and printed as PDF,
keeps the full width.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 13:00:20 +02:00
Grovy311
cd89c4a499 Add buildings above floors and a building structure page
Projects with several buildings could not be structured: floors and rooms
hung directly off the project. Floors can now belong to a building
(migration 0009: table buildings, nullable floors.building_id). Rooms and
distribution boards keep their floor; their building follows from it.
Existing floors stay without a building.

Buildings use the location-structure command store with
project-building.insert/.update/.delete, inverses and persistent Undo/Redo;
deleting a building with assigned floors is rejected. Floor commands carry
buildingId since command version 2. Version 1 floor commands from existing
history predate buildings and are upgraded with buildingId = null before
they are executed and persisted, so forward and inverse keep one version.

Project snapshot schema 7 stores buildings and floor.buildingId; versions
1-6 are upgraded without buildings. Restore and portable transfer include
buildings, and the transfer remaps building ids.

Buildings, floors and rooms move from the project overview to their own
page /projects/:id/struktur with three columns (Gebäude -> Etagen -> Räume)
that filter each other, and a sidebar entry. Floor selects in the board and
room dialogs are grouped by building. Unchanged dialogs close without a
command. Details in docs/building-structure.md; see issue #6.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 12:52:34 +02:00
Grovy311
79fcb75ffb Create client ids without crypto.randomUUID
crypto.randomUUID() is only defined in secure contexts (HTTPS or
localhost). Opened over plain HTTP from another machine in the LAN, the
circuit list editor failed with "crypto.randomUUID is not a function"
whenever it created a circuit, device row, circuit group or distribution
board component, including typing into the -frei- row.

createClientId() uses crypto.randomUUID() where available and otherwise
builds an RFC 4122 version 4 UUID from crypto.getRandomValues(), which
works in every context. AGENTS.md notes the rule.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 12:01:43 +02:00
Grovy311
7692699ee2 Add print cover fields and office profile
- Project settings gain siteAddress, workStage, projectLead and
  projectEditor (project.update-settings schema version 3, migration 0009);
  versions 2 and 1 stay executable and keep the current cover values.
  Snapshot schema 6 carries the fields; older versions upgrade with null.
- Global office profile (office name/address) next to the document logo:
  table document_branding_settings, PUT /api/document-branding/office,
  editable from the print view toolbar.
- Cover page reads all fields; empty values show the "[ergänzen]" marker.
  The Planstände editor column shows the project editor.
- Shared logo constants moved to a dependency-free module so the Next.js
  bundler can import them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 10:39:18 +02:00
Grovy311
4779e4a1a7 Add print view, board info card and document logo upload
- Seitenansicht (/projects/:projectId/print): tabular cover page, board
  overview with supply structure and power sums, one plan per board with a
  repeating title block; PDF via the browser print dialog with named @page
  rules (A4 portrait cover, A4/A3 landscape plans, page x of y).
- Distribution-board info card (board number, location, fed-from, remark)
  in the board edit dialog, persisted through the additively extended
  distribution-board.update command (migration 0008, snapshot schema 6,
  legacy subtree commands normalized).
- Global document logo upload (PNG/JPEG/SVG, max 2 MB) outside project
  revisions and snapshots.
- fed-from stays free text; the overview hierarchy and cumulated sums are
  preliminary until the feed link is modeled.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-26 10:38:59 +02:00
a17e2e3f4b Merge remote-tracking branch 'origin/feature/amev-picker-and-collapsible-sidebar' 2026-08-06 22:01:54 +02:00
64ccd1f829 Add dark mode toggle in the sidebar
Adds a persistent dark/light theme toggle (localStorage +
data-bs-theme on <html>) so it applies globally, including the
circuit editor route which has no visible sidebar. An inline
beforeInteractive script sets the theme before hydration to avoid a
flash of the wrong theme.

Bootstrap components pick up data-bs-theme automatically; the custom
circuit-grid CSS previously used ~150 hardcoded hex colors, all
converted to semantic tokens in globals.css with light/dark values.

Verified with a headless-browser pass across the project list, project
detail page, circuit editor, project-device drawer and a settings
modal in both themes; no console errors.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-08-06 21:56:21 +02:00
b45dc5002d Fix code-review findings across domain, persistence, server and frontend
Full-codebase review turned up five real correctness/security bugs and
a dozen smaller inconsistencies; all are fixed here with matching test
coverage:

- BMK uniqueness silently allowed German-umlaut duplicates ("Ä1" vs
  "ä1") because the DB's normalized index only folds ASCII case. Added
  a shared Unicode-aware pre-check used by every circuit/component
  insert and rename path (one of which had no pre-check at all).
- CircuitDeviceRow.simultaneityFactor had no upper bound at the row
  level (command model and snapshot/restore schema), unlike every
  sibling entity, letting a bad value silently corrupt power totals.
- Grid cell editing silently misread German thousands-separator input
  ("1.500" parsed as 1.5); "." is now rejected outright with a clear
  message instead of guessing.
- The editor's shared command runner (runCommand/applyHistory) had no
  re-entrancy guard, so a double click/drop could fire the same
  command twice and race a BMK collision or revision conflict. Added a
  synchronous ref guard plus isSaving on the buttons that lacked it.
- GET .../next-identifier leaked circuit-numbering state for sections
  in other projects (no ownership check, 400 instead of 404). Moved
  under /projects/:projectId and scoped it.

Also: added the missing circuits.section_id / circuit_device_rows.
circuit_id indexes (migration 0006), gave FormModal a focus trap /
Escape-to-close / focus restore and rebuilt ProjectSettingsModal on
top of it instead of duplicated markup, removed dead code (3 orphaned
domain model files, an unused persistence helper, a wrapper only used
by its own test), pointed the project page at GET /projects/:id
instead of listing+filtering client-side, closed the gap between the
documented 18 MB CSV limit and the ~17.17 MiB actually enforced, added
missing upper bounds on several free-text fields, filled in nine
missing German labels in the revision timeline, replaced a
key-order-fragile JSON.stringify equality check with a real field
comparison, made an implicit sort-order assumption in three
renumbering helpers explicit, cleared the sidebar's target selection
when it no longer resolves after a tree reload, and fixed
updateGlobalDevice to check-then-write instead of write-then-check.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-08-06 21:31:16 +02:00
Grovy311
9bd22dfcb7 Add AMEV Gleichzeitigkeitsfaktor-Auswähler und einklappbare Seitenleiste
- Gzf-Picker-Modal mit AMEV-Tabelle 3 (Planungshilfe für elektrische
  Leistungsbilanzen) im Projektgerät-Modal und im globalen Geräteformular
- Docker-Deploy-Tooling (docker-start.sh, run-migrations.js) für den
  produktiven Container
- Seitenleiste ist jetzt einklappbar (Icon-only, Zustand in localStorage)
2026-08-03 17:07:14 +02:00
74bea1a3c9 Add Revit circuit list object feed 2026-08-02 18:59:01 +02:00
dac19b093c Add external row quantity foundation 2026-08-02 18:26:22 +02:00
bc2bc7ece5 Add Revit catalog creation flow 2026-08-02 18:08:18 +02:00
ab2449419b Add Revit initial import wizard 2026-08-02 17:52:21 +02:00
d0fc1a7caf Widen Revit CSV dialog 2026-08-02 17:10:22 +02:00
a9d6301753 Add Revit CSV project dialog 2026-08-02 16:59:18 +02:00
44b6fde940 Add public building project setting 2026-07-31 17:41:30 +02:00
facf788ce8 Remove circuit structure preview 2026-07-31 14:52:37 +02:00
1eed19ef6b Add editable project floors and rooms 2026-07-31 14:46:06 +02:00
1e3c721cfa Derive project device phases from category 2026-07-31 14:37:45 +02:00
5fb81bab04 Support decimal commas and cell units 2026-07-31 14:33:47 +02:00
734a2bcfc4 Create clean release database baseline 2026-07-31 14:07:26 +02:00
5bee3cb103 Add distribution board copy and delete controls 2026-07-31 12:03:52 +02:00
86f1d42e60 Expose distribution board copy and delete API 2026-07-31 11:59:31 +02:00
bd8dd09f79 Open circuit protection from grid cell 2026-07-31 10:02:11 +02:00
54874f9fcb Render circuit protection values 2026-07-31 09:56:49 +02:00
2964205a27 Show circuit protection in saved layouts 2026-07-31 09:45:58 +02:00
f4bfef9071 Merge branch 'main' into feature/multiplesections 2026-07-31 09:00:39 +02:00
2d97fafce9 Restore circuit drag placement 2026-07-31 08:33:41 +02:00
ab989cc637 Delete populated circuit groups safely 2026-07-31 08:01:55 +02:00
93ec294759 Move circuits between groups 2026-07-31 07:58:42 +02:00
be9c6f0d52 Renumber circuit groups explicitly 2026-07-31 07:53:07 +02:00
0cb280ddb2 Reorder circuit groups 2026-07-31 07:47:45 +02:00
8898117ed4 Configure circuit protection 2026-07-31 07:45:48 +02:00
0c92fbd09e Manage circuit groups 2026-07-31 07:32:46 +02:00
756e307bd8 Manage distribution board components 2026-07-31 07:29:25 +02:00
31589875b5 Render protected circuit structure 2026-07-31 07:22:26 +02:00
ac21d6eb5d WIP multiple sections 2026-07-30 20:27:17 +02:00
7a9530a914 Expose protected tree structure 2026-07-30 20:14:45 +02:00
99bdf6491b Persist populated group deletion 2026-07-30 20:10:10 +02:00
3399fcd88b Persist circuit group moves 2026-07-30 20:03:11 +02:00
07925b2fd9 Persist circuit group renumbering 2026-07-30 19:56:59 +02:00
e702712bd8 Add circuit group reordering 2026-07-30 19:49:27 +02:00
1250f9a6af Add circuit group commands 2026-07-30 19:46:55 +02:00
69b020339e Add component update commands 2026-07-30 19:42:09 +02:00
604604f056 Add component structure commands 2026-07-30 19:38:48 +02:00
Grovy311
704f4df2a8 Apply Petrol/Volt/Kupfer design system and project sidebar
Bring the Econsult-family design tokens (see design-system-econsult.md)
into leistungsbilanz-ts and add a persistent sidebar for the projects
area, mirroring elt-planung-suite / Einsatz-Orga. The sidebar lists all
projects and, inside a project, jumps to its sections; the tree editor
stays sidebar-free since it needs the full width. The projects overview
page is decluttered to a single stacked column (create/import/global
devices) now that the project list lives in the sidebar.
2026-07-30 17:40:11 +02:00