Current Product Backlog
This document records the next agreed product improvements. It describes requirements and intended sequencing, not proof of implementation.
Circuit List Editor
- Collect the remaining editor interaction issues before changing additional behavior.
Project History
- Every listed logical snapshot, including automatic snapshots, must be explicitly restorable from the project history UI.
- Show which project change produced a snapshot. Prefer immutable revision metadata over storing a second free-form description of the same change.
- Keep restoration auditable as a new project revision and preserve persistent undo/redo.
Distribution Boards
- Assign an optional project floor to a distribution board.
- Store a supply classification for each distribution board:
AV(Allgemeine Stromversorgung)SV(Sicherheitsstromversorgung)EV(Ersatzstromversorgung)USV(Unterbrechungsfreie Stromversorgung)MSR(Mess-, Steuerungs- und Regelungstechnik)SiBe(Sicherheitsbeleuchtung)
- Let project settings select which catalog supply types are used in a project. Distribution-board dialogs offer only that selection; a type in use cannot be disabled.
- Include both fields in project snapshots and portable project export/import.
- Persist changes through project commands so they remain undoable after a restart.
Device Voltage Derivation
- Derive voltage from the selected phase type and the project settings:
- single-phase uses the project's single-phase voltage;
- three-phase uses the project's three-phase voltage.
- Voltage is not editable on global devices, project devices or circuits. Global devices store only their phase; copying one into a project derives the target project's voltage.
- Project-device voltage follows its phase. Circuit voltage follows the section phase; an unassigned circuit is three-phase only when all assigned device rows with a valid phase are three-phase.
- Changing project voltage settings updates all project devices and circuits atomically in the same persistent Undo/Redo step.
- Database migration
0019and snapshot schema version5normalize older stored values. Version-four and older imports remain supported and are normalized while being upgraded.
Circuit List Power Summary
- Show the total power of every circuit section.
- Show the unadjusted total power of the complete distribution board.
- Store a distribution-board simultaneity factor between zero and one in the distribution-board settings.
- Show the distribution-board total after applying that factor.
- Preserve the factor in project commands, snapshots and portable project transfers.
- Keep column visibility and order as a project-specific UI preference so all distribution boards in the same project open with the same columns.
Recommended Sequence
- Distribution-board floor and supply fields.
- Device voltage derivation without overrides.
- Snapshot-to-revision descriptions and history presentation.
- Distribution-board power summary and project column layout.
The Revit/CSV/IFCGUID round-trip remains a separate jointly planned phase and must not be inferred from these tasks.