Per-circuit cross-section recommendation as a separate module attached to the circuit list. It never writes project data itself: "Übernehmen" applies cable type, cross-section and length through the regular circuit.update command, so revisions and Undo/Redo stay intact. - Pure domain module (src/cable-sizing) with IEC 60364-5-52:2009 Annex B tables for PVC and XLPE, copper and aluminium, methods A1, A2, B1, B2, C, D1, D2 and E. Every value was cross-checked against public reproductions; where sources differ the lower value is used (docs/cable-sizing-module.md). - Temperature and grouping between table values round to the safer value; values outside the tables return no result instead of a factor of 1. Ground methods use B.52.18 (D2) and B.52.19 A (D1). - Overload protection: circuit-breakers In <= Iz; gG fuses additionally I2 <= 1.45 Iz with I2 = 1.6/1.9/2.1 In. - Inputs prefilled from the circuit: power, phase (group or device rows), project voltage, power-weighted cos phi, length and protective device. - Opened from a "Leitungsberechnung" button in the row actions, not from a grid cell, so cable cells keep the spreadsheet behavior. - Stateless API under /api/cable-sizing; no database table or migration. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
52 lines
2.5 KiB
Markdown
52 lines
2.5 KiB
Markdown
# Dokumentationsübersicht
|
||
|
||
Diese Seite ist der Einstieg in die Projektdokumentation. Aussagen zum aktuellen
|
||
System stehen unter „Aktuell“. Zukunftsentwürfe und historische Unterlagen sind
|
||
ausdrücklich getrennt und dürfen nicht als bereits implementiert verstanden werden.
|
||
|
||
## Aktuell
|
||
|
||
- [Aktuelle Systemarchitektur](current-architecture.md) – Laufzeit, Modulgrenzen,
|
||
Datenfluss und unterstützte Codepfade
|
||
- [Stromkreislisten-Architektur](circuit-list-editor-architecture.md) –
|
||
fachliches Modell und Grid-Aufteilung
|
||
- [Editor-Interaktionen](circuit-list-editor-interactions.md) – Tastatur,
|
||
Drag-and-drop, Sortierung, Filterung und Undo/Redo
|
||
- [Editor-API](circuit-list-editor-api.md) – unterstützte Circuit-First-Endpunkte
|
||
- [Bekannte Einschränkungen](circuit-list-editor-known-limitations.md) –
|
||
bewusst noch nicht implementierte oder begrenzte Funktionen
|
||
- [Leitungsberechnung](cable-sizing-module.md) – optionales Rechenmodul,
|
||
Rechenweg, Datenbasis und Prüfnachweis der Tabellen
|
||
|
||
## Entwicklung und Betrieb
|
||
|
||
- [Entwicklungs- und Contributor-Workflow](development-workflow.md)
|
||
- [Deployment und Betrieb](deployment.md)
|
||
|
||
## Zukunftsarchitektur
|
||
|
||
- [Projektversionen und externer Modellaustausch](project-history-and-external-model-architecture.md)
|
||
- [LLM-Kontext für die Revit-Anforderungsplanung](revit-requirements-llm-context.md)
|
||
- [Revit-CSV-Anforderungen](spec/revit-csv-integration-requirements.md)
|
||
- [Phase-14-Audit und Implementierungsplan](spec/revit-csv-phase-14-audit-and-plan.md)
|
||
- [Zukünftige Dimensionierung](spec/06-future-sizing-and-calculations.md)
|
||
- [Roadmap und Phasen](spec/07-implementation-phases-todo.md)
|
||
- [Aktueller Produkt-Backlog](spec/08-current-product-backlog.md)
|
||
|
||
## Fachliche Referenzspezifikation
|
||
|
||
Die folgenden Dokumente beschreiben Zielregeln und Anforderungen. Nicht jeder
|
||
Punkt ist bereits umgesetzt; der aktuelle Stand ergibt sich aus Architektur,
|
||
Limitierungen und Roadmap.
|
||
|
||
- [Domänenkontext](spec/01-domain-context.md)
|
||
- [Funktionale Anforderungen](spec/02-functional-requirements.md)
|
||
- [Datenmodellkonzept](spec/03-data-model-concept.md)
|
||
- [UI- und Interaktionsanforderungen](spec/04-ui-interaction-requirements.md)
|
||
- [Verknüpfte Projektgeräte und Synchronisierung](spec/05-linked-devices-and-sync.md)
|
||
- [Verteilerkomponenten und Schutzgruppen](spec/09-distribution-board-components-and-protection-groups.md)
|
||
|
||
## Archiv
|
||
|
||
- [Frühe Codex-Promptvorlagen](archive/initial-codex-prompts.md) – historischer
|
||
Arbeitsstand, keine aktuelle Implementierungsanweisung
|