forked from jappel/leistungsbilanz-ts
168 lines
8.2 KiB
Markdown
168 lines
8.2 KiB
Markdown
# Current Product Backlog
|
||
|
||
This document records the next agreed product improvements. It describes
|
||
requirements and intended sequencing, not proof of implementation.
|
||
|
||
## Circuit List Editor
|
||
|
||
- Collect the remaining editor interaction issues before changing additional
|
||
behavior.
|
||
|
||
## Distribution Board Components and Protection Groups
|
||
|
||
- [x] Implement the agreed protected circuit-group and distribution-board
|
||
component model in phased work packages.
|
||
- [x] Phase A: central protection catalog, validation, defaults and pure grouped
|
||
BMK rules.
|
||
- [x] Phase B1: relational group, component and protection tables with shared
|
||
BMK uniqueness.
|
||
- [x] Phase B2: complete snapshot/transfer schema for the supported project
|
||
state.
|
||
- [x] Phase C1: new-board command with three groups and fixed header
|
||
components.
|
||
- [x] Phase C2a1: persistent insert/delete commands for mutable group
|
||
protection and auxiliary components.
|
||
- [x] Phase C2a2: component update and reorder commands.
|
||
- [x] Phase C2b1: empty-group insert/update/delete commands.
|
||
- [x] Phase C2b2: complete group reorder command.
|
||
- [x] Phase D1a: deterministic collision-aware group-renumber plan.
|
||
- [x] Phase D1b: persistent collision-safe group-renumber command.
|
||
- [x] Phase D2a: deterministic same-category circuit-move plan.
|
||
- [x] Phase D2b: persistent same-category circuit-move command.
|
||
- [x] Phase D3a: complete validated group-subtree snapshot and warning summary.
|
||
- [x] Phase D3b: persistent populated-group delete/restore command.
|
||
- [x] Phase E1: tree read model for components, groups and protection devices.
|
||
- [x] Phase E2a: pure header/group/footer structure projection.
|
||
- [x] Phase E2b: render the structure projection in the editor grid.
|
||
- [x] Phase E3a: create, edit and delete mutable group and footer components.
|
||
- [x] Phase E3b1: create, rename and safely delete empty circuit groups.
|
||
- [x] Phase E3b2a: persistent circuit-protection update command.
|
||
- [x] Phase E3b2b: circuit-protection defaults on insert and editor modal.
|
||
- [x] Phase E4a: persistent same-category group reorder controls.
|
||
- [x] Phase E4b: explicit group renumber, circuit moves and populated-delete warning.
|
||
- [x] Explicit same-category group renumbering updates prefixes and all child BMK atomically.
|
||
- [x] Single-circuit moves between same-category groups with automatic next-free BMK assignment.
|
||
- [x] Populated-group delete warning and explicit subtree deletion.
|
||
- [x] Phase E: editor projection and editing.
|
||
- [x] Phase F: documentation and full GUI verification.
|
||
- [ ] Keep full electrical sizing and cable-dimensioning rules separate until
|
||
the planner supplies the calculation requirements. The optional per-circuit
|
||
cable sizing module (`docs/cable-sizing-module.md`) exists; its supported
|
||
tables were confirmed against DIN VDE 0298-4:2023-06 with
|
||
Berichtigung 1:2023-10. Unsupported arrangements stay explicitly blocked.
|
||
- Detailed specification:
|
||
`docs/spec/09-distribution-board-components-and-protection-groups.md`
|
||
|
||
## First Release Baseline
|
||
|
||
The pre-release cleanup established the following compatibility boundary:
|
||
|
||
- [x] Pre-baseline databases, portable JSON exports, logical snapshots and
|
||
persisted command histories are explicitly unsupported.
|
||
- [x] Migration `0000` builds the complete supported schema on an empty
|
||
database.
|
||
- [x] The development migration chain and Drizzle metadata were replaced
|
||
before any supported release depended on them.
|
||
- [x] Upgrade-only database, snapshot and command compatibility paths were
|
||
removed.
|
||
- [x] Pre-cleanup development history remains available through Git history.
|
||
- [x] Clean installation, migration, startup and core workflows were verified
|
||
against an empty database.
|
||
- [ ] Mark this compatibility boundary with the first supported release tag.
|
||
- After that release, every published migration is immutable and later schema
|
||
changes must use new additive migrations.
|
||
|
||
## Project History
|
||
|
||
- [x] Every listed logical snapshot, including automatic snapshots, must be
|
||
explicitly restorable from the project history UI.
|
||
- [x] Show which project change produced a snapshot. Prefer immutable revision
|
||
metadata over storing a second free-form description of the same change.
|
||
- [x] Keep restoration auditable as a new project revision and preserve persistent
|
||
undo/redo.
|
||
|
||
## Distribution Boards
|
||
|
||
- [x] Assign an optional project floor to a distribution board.
|
||
- [x] Store a supply classification for each distribution board:
|
||
- `AV` (Allgemeine Stromversorgung)
|
||
- `SV` (Sicherheitsstromversorgung)
|
||
- `EV` (Ersatzstromversorgung)
|
||
- `USV` (Unterbrechungsfreie Stromversorgung)
|
||
- `MSR` (Mess-, Steuerungs- und Regelungstechnik)
|
||
- `SiBe` (Sicherheitsbeleuchtung)
|
||
- [x] Let project settings select which catalog supply types are used in a
|
||
project. Distribution-board dialogs offer only that selection; a type in
|
||
use cannot be disabled.
|
||
- [x] Include both fields in project snapshots and portable project
|
||
export/import.
|
||
- [x] Persist changes through project commands so they remain undoable after a
|
||
restart.
|
||
|
||
## Device Voltage Derivation
|
||
|
||
- [x] Derive voltage from the selected phase type and the project settings:
|
||
- single-phase uses the project's single-phase voltage;
|
||
- three-phase uses the project's three-phase voltage.
|
||
- [x] Voltage is not editable on global devices, project devices or circuits.
|
||
Global devices store only their phase; copying one into a project derives
|
||
the target project's voltage.
|
||
- [x] Project-device voltage follows its phase. Circuit voltage follows the
|
||
section phase; an unassigned circuit is three-phase only when all assigned
|
||
device rows with a valid phase are three-phase.
|
||
- [x] Changing project voltage settings updates all project devices and circuits
|
||
atomically in the same persistent Undo/Redo step.
|
||
- [x] Baseline migration `0000` stores only canonical derived values.
|
||
Pre-baseline imports are intentionally unsupported.
|
||
|
||
## Building Classification
|
||
|
||
- [x] Store whether a project represents a public building.
|
||
- [x] Edit the value in the project settings and preserve it through persistent
|
||
Undo/Redo, snapshots and portable project transfers.
|
||
- [x] Provide the value as an explicit future sizing input for selecting
|
||
halogen-free cables and lines; automatic sizing remains deferred.
|
||
|
||
## Circuit List Power Summary
|
||
|
||
- [x] Show the total power of every circuit section.
|
||
- [x] Show the unadjusted total power of the complete distribution board.
|
||
- [x] Store a distribution-board simultaneity factor between zero and one in
|
||
the distribution-board settings.
|
||
- [x] Show the distribution-board total after applying that factor.
|
||
- [x] Preserve the factor in project commands, snapshots and portable project
|
||
transfers.
|
||
- [x] Keep column visibility and order as a project-specific UI preference so
|
||
all distribution boards in the same project open with the same columns.
|
||
|
||
## Integrated Contributor Features (September 2026)
|
||
|
||
- [x] Client ids without secure-context browser APIs (`createClientId`).
|
||
- [x] Icon actions, compact column headers and the AMEV picker in the circuit
|
||
list; icon actions and collapsible filters on the project overview.
|
||
- [x] Print view with cover, board overview, board plans, board info card and
|
||
office branding.
|
||
- [x] Buildings above floors and a dedicated building structure page.
|
||
- [x] Optional net room area with sums per floor and building.
|
||
- [x] Optional cable-sizing module for one circuit on demand
|
||
(DIN VDE 0298-4:2023-06 with Berichtigung 1).
|
||
- [x] Rough power balance for LPH 2/3 by cost group, including the comparison
|
||
with the detailed balance and the explicit copy of one row as a
|
||
ProjectDevice.
|
||
- [x] Logical distribution-board feed link with an optional feeding circuit,
|
||
recursive load rollup and deletion guards (#3).
|
||
|
||
Open follow-ups (Gitea issues): bill of quantities export (#5), area-based loads in W/m² for
|
||
ProjectDevices and device rows (#20).
|
||
|
||
## Recommended Sequence
|
||
|
||
1. [x] Distribution-board floor and supply fields.
|
||
2. [x] Device voltage derivation without overrides.
|
||
3. [x] Snapshot-to-revision descriptions and history presentation.
|
||
4. [x] Distribution-board power summary and project column layout.
|
||
|
||
The Revit/Linear-XLSX round-trip is now the separately planned active Phase 14.
|
||
It uses exact Worksharing-ID identity and must not be inferred from these
|
||
unrelated backlog tasks. See
|
||
[the R0–R10 plan](revit-excel-phase-14-plan.md).
|