## Scope
The circuit-first editor uses tree, circuit, row and project-device endpoints.
All paths below are mounted below `/api`. There is no Consumer application API.
Project responses from `GET /projects` and `GET /projects/:projectId` include
`currentRevision`. It currently exposes the persisted revision foundation only;
no public undo or redo command exists yet.
### Project History State
- `GET /projects/:projectId/history`
- returns `currentRevision`, `undoDepth`, `redoDepth` and the current top
change-set id for both persistent stacks
- is read-only; the editor does not consume it yet
## Circuit-First Endpoints
### Distribution Board Setup
- `POST /projects/:projectId/distribution-boards`
- atomically creates the distribution board, its circuit list and all default circuit sections
### Tree Endpoint
- `GET /projects/:projectId/circuit-lists/:circuitListId/tree`
- Purpose: returns section/circuit/device-row tree with calculated row and circuit totals.
Response sketch:
```json
{
"circuitListId": "cl_1",
"sections": [
{
"id": "sec_1",
"key": "lighting",
"prefix": "-1F",
"circuits": [
{
"id": "cir_1",
"equipmentIdentifier": "-1F1",
"circuitTotalPower": 4.2,
"deviceRows": [
{
"id": "row_1",
"displayName": "Office lights",
"rowTotalPower": 1.8
}
]
}
]
}
]
}
```
### Circuit CRUD
- `POST /projects/:projectId/circuit-lists/:circuitListId/circuits`
- create circuit in list/section
- `POST /projects/:projectId/circuit-lists/:circuitListId/circuits-with-device-rows`
- atomically create one circuit and one or more initial device rows
- `PATCH /circuits/:circuitId`
- update circuit-level fields (BMK, protection, cable, reserve flag, etc.)
- `DELETE /circuits/:circuitId`
- delete circuit (and related rows via DB relations)
- `GET /circuit-sections/:sectionId/next-identifier`
- preview next identifier for section (`prefix + maxSuffix + 1`)
Request sketch (`POST .../circuits`):
```json
{
"sectionId": "sec_1",
"equipmentIdentifier": "-2F14",
"displayName": "Sockets East",
"sortOrder": 140
}
```
### Device Row CRUD
- `POST /circuits/:circuitId/device-rows`
- create row inside a circuit
- `PATCH /circuit-device-rows/:rowId`
- update row values
- `DELETE /circuit-device-rows/:rowId`
- delete row
### Move Device Row
- `PATCH /circuit-device-rows/:rowId/move`
- Purpose: move one row to existing circuit or to newly created circuit in target section.
Request sketch:
```json
{
"targetCircuitId": "cir_target"
}
```
or
```json
{
"targetSectionId": "sec_target",
"createNewCircuit": true
}
```
### Bulk Move Device Rows
- `PATCH /circuit-device-rows/move-bulk`
- Purpose: move multiple rows in one command flow.
Request sketch:
```json
{
"rowIds": ["row_1", "row_2"],
"targetCircuitId": "cir_target"
}
```
### Reorder Circuits
- `PATCH /circuit-sections/:sectionId/circuits/reorder`
- Purpose: persist explicit circuit order within one section.
Request sketch:
```json
{
"orderedCircuitIds": ["cir_2", "cir_1", "cir_3"]
}
```
### Renumber Section
- `POST /circuit-sections/:sectionId/renumber`
- Purpose: explicit renumbering by section prefix; never implicit on move/sort.
### Safe Equipment Identifier Update
- `PATCH /circuit-sections/:sectionId/equipment-identifiers`
- Purpose: apply explicit per-circuit identifiers safely even with unique constraints.
Request sketch:
```json
{
"identifiers": [
{ "circuitId": "cir_1", "equipmentIdentifier": "-2F1" },
{ "circuitId": "cir_2", "equipmentIdentifier": "-2F2" }
]
}
```
## Removed Legacy Endpoints
The former `/consumers` read/write endpoints were removed after every retained
consumer had a verified Circuit-First migration mapping. Database upgrade tooling
reads retained legacy rows directly; application features must use the Circuit-First
endpoints above.
## Linked Project Device Review
- `GET /project-devices/projects/:projectId/:projectDeviceId/links`
- returns all linked circuit device rows with distribution-board/circuit context and field differences
- `POST /project-devices/projects/:projectId/:projectDeviceId/synchronize`
- applies only explicitly selected fields to explicitly selected linked rows
- `POST /project-devices/projects/:projectId/:projectDeviceId/restore`
- restores the captured pre-sync values for session-local undo
- `POST /project-devices/projects/:projectId/:projectDeviceId/disconnect`
- disconnects explicitly selected rows without changing their local values
- `POST /project-devices/projects/:projectId/:projectDeviceId/reconnect`
- restores a disconnected link if the row has not been linked elsewhere meanwhile
`displayName` is included in the comparison but is not selected by default in the UI. Updating a
project device never triggers synchronization implicitly.