# Circuit List Editor Known Limitations
|
|
|
|
- All currently supported Circuit and CircuitDeviceRow editor writes use
|
|
persistent project commands and project-wide toolbar undo/redo, including
|
|
moves, atomic multi-section reorders and explicit renumbering. Undo/redo
|
|
eligibility is restored from server history after a page reload.
|
|
- The project page exposes the paginated revision timeline; the circuit editor
|
|
itself currently exposes only the next eligible Undo/Redo actions.
|
|
- Named and automatic logical project snapshots can be listed and restored
|
|
through the project page with persistent Undo/Redo. Automatic snapshots are
|
|
created every 25 revisions and only their newest 12 entries are retained.
|
|
- The current Revit/CSV foundation and confirmed initial import are a legacy
|
|
starting point. The active Phase-14 plan replaces them with the Linear XLSX
|
|
exchange and exact Worksharing-ID identity.
|
|
R2 must pass a real Linear return-import check before database cutover in R3.
|
|
Existing-row assignment, move and detach plus creation of an external-only
|
|
row in an existing or newly created circuit have atomic persistent commands.
|
|
Their API planning and editor UI, follow-up import, conflict review and return
|
|
export are pending.
|
|
- Persistence currently targets local SQLite; PostgreSQL is an architectural option, not an implemented runtime.
|
|
- The global device library supports basic CRUD and copy operations, but has no
|
|
versioning, permissions or controlled synchronization model.
|
|
- There is no automatic sizing of all circuits. The optional cable sizing
|
|
module suggests a cross-section for one circuit on demand using
|
|
DIN VDE 0298-4:2023-06 with Berichtigung 1:2023-10. It excludes direct
|
|
burial, grouped method E and neutral-current sizing above 33 % third
|
|
harmonic, and it does not check short-circuit withstand, disconnection time
|
|
or selectivity. See `docs/cable-sizing-module.md`.
|
|
- Sorting is view-only until users explicitly apply sorted order.
|
|
- Complete-circuit drag supports one circuit at a time between groups of the
|
|
same category. Cross-category moves and multi-circuit moves across group
|
|
boundaries are intentionally rejected; multi-circuit reorder inside one
|
|
group remains supported.
|
|
- Protection and cable values are planner-owned manual selections. The later
|
|
sizing/warning engine does not yet validate them against load, length or
|
|
voltage-drop rules.
|
|
- One logical incoming feed per distribution board is supported. A second or
|
|
replacement feed with changeover semantics (for example SV/SiBe) is still a
|
|
follow-up. `fedFrom` remains the free-text field for external sources and
|
|
supplementary notes. Revit does not yet propose logical feed links.
|
|
- A logical link without a selected feeding circuit appears in the hierarchy,
|
|
but deliberately contributes no load to an upstream circuit until the planner
|
|
selects that circuit (see `docs/print-view.md`).
|
|
- The print view uses a kbp corporate design derived from logo and
|
|
presentation material. Snapshots do not record an editor, so the cover's
|
|
Planstände list shows the project's current editor for every entry. On screen, long
|
|
board plans are not split into pages; pagination happens in the browser print
|
|
dialog.
|