This repository contains a web application for creating, editing, calculating, and documenting electrical power balances for building-services electrical planning.
|
||
|
||
The application is intended for small internal use by approximately 2–3 concurrent users. It should support practical planning workflows, not an over-engineered enterprise architecture.
|
||
|
||
The domain is electrical building planning, especially German TGA / ELT planning. Important concepts include:
|
||
|
||
- Power balance / Leistungsbilanz
|
||
- Distribution boards / Verteilungen
|
||
- Electrical consumers / Verbraucher
|
||
- Installed power / installierte Leistung
|
||
- Demand factor / Gleichzeitigkeitsfaktor
|
||
- Calculated demand power / berechnete Leistung
|
||
- Voltage, current, phases, cos phi
|
||
- Device groups and individual devices
|
||
- Project-based calculation and documentation
|
||
|
||
Use English identifiers in code, database fields, interfaces, classes, and file names. German wording is allowed and preferred in UI labels, reports, and domain-facing text.
|
||
|
||
## Main Goal
|
||
|
||
Build a maintainable web application that allows users to:
|
||
|
||
- Create and manage projects
|
||
- Define electrical distributions or calculation areas
|
||
- Add individual electrical consumers
|
||
- Add grouped consumers with quantity
|
||
- Assign technical parameters to consumers
|
||
- Calculate installed and demand power
|
||
- Structure consumers by project, distribution, area, system, or category
|
||
- Export or print a usable power-balance report later
|
||
|
||
The application should be practical for electrical planners and should keep the data model understandable.
|
||
|
||
## Technology Direction
|
||
|
||
Preferred stack:
|
||
|
||
- TypeScript
|
||
- Node.js backend
|
||
- SQLite database for the initial version
|
||
- ORM is allowed and preferred if it improves type safety and maintainability
|
||
- Drizzle ORM is preferred for a more explicit SQL-oriented approach
|
||
- Prisma is acceptable if the project already uses it
|
||
- Frontend may be React-based if a UI is implemented
|
||
- Docker support for local development is desired
|
||
|
||
Do not introduce unnecessary infrastructure such as PostgreSQL, Redis, Kubernetes, microservices, message queues, or complex event systems unless explicitly requested.
|
||
|
||
SQLite is sufficient for the expected initial workload.
|
||
|
||
## Architecture Principles
|
||
|
||
Keep the application modular, but avoid excessive abstraction.
|
||
|
||
Preferred structure:
|
||
|
||
```text
|
||
src/
|
||
├─ domain/
|
||
│ ├─ models/
|
||
│ ├─ services/
|
||
│ └─ calculations/
|
||
├─ db/
|
||
│ ├─ schema/
|
||
│ ├─ migrations/
|
||
│ └─ repositories/
|
||
├─ server/
|
||
│ ├─ routes/
|
||
│ ├─ controllers/
|
||
│ └─ middleware/
|
||
├─ frontend/
|
||
│ ├─ components/
|
||
│ ├─ pages/
|
||
│ └─ utils/
|
||
└─ shared/
|
||
├─ types/
|
||
└─ validation/
|
||
```
|
||
|
||
The exact structure may be simplified if the project is still small.
|
||
|
||
Use object-oriented design where it is useful for domain behavior, but do not force everything into classes.
|
||
|
||
Good candidates for classes:
|
||
|
||
- Project
|
||
- PowerBalance
|
||
- DistributionBoard
|
||
- Consumer
|
||
- ConsumerGroup
|
||
- CalculationService
|
||
- ReportGenerator
|
||
|
||
Good candidates for interfaces/types:
|
||
|
||
- DTOs
|
||
- API request/response shapes
|
||
- ORM result types
|
||
- Configuration objects
|
||
- Form data
|
||
- Validation schemas
|
||
|
||
Avoid duplicating the same model excessively across domain, database, API, and frontend. Some separation is acceptable, but keep mappings simple and explicit.
|
||
|
||
## Naming Conventions
|
||
|
||
Use English names in code.
|
||
|
||
Examples:
|
||
|
||
- `Project`
|
||
- `PowerBalance`
|
||
- `DistributionBoard`
|
||
- `Consumer`
|
||
- `ConsumerGroup`
|
||
- `installedPower`
|
||
- `demandFactor`
|
||
- `demandPower`
|
||
- `ratedCurrent`
|
||
- `powerFactor`
|
||
- `quantity`
|
||
- `voltage`
|
||
- `phaseCount`
|
||
|
||
Use PascalCase for classes, interfaces, React components, and types.
|
||
|
||
Use camelCase for variables, properties, functions, and methods.
|
||
|
||
Use kebab-case for file names unless the local framework convention requires otherwise.
|
||
|
||
Examples:
|
||
|
||
```text
|
||
power-balance.service.ts
|
||
consumer.model.ts
|
||
distribution-board.repository.ts
|
||
calculation-utils.ts
|
||
```
|
||
|
||
## Domain Model Guidelines
|
||
|
||
A consumer must still have a quantity. This allows the same structure to represent either a single device or a grouped device entry.
|
||
|
||
Example:
|
||
|
||
```ts
|
||
type Consumer = {
|
||
id: string;
|
||
projectId: string;
|
||
distributionBoardId?: string;
|
||
name: string;
|
||
category?: string;
|
||
quantity: number;
|
||
installedPowerPerUnit: number;
|
||
installedPowerTotal: number;
|
||
demandFactor: number;
|
||
demandPower: number;
|
||
voltage?: number;
|
||
phaseCount?: 1 | 3;
|
||
powerFactor?: number;
|
||
note?: string;
|
||
};
|
||
```
|
||
|
||
The calculated fields may either be persisted or calculated dynamically. Prefer dynamic calculation first unless persistence is needed for reporting, auditability, or performance.
|
||
|
||
## Calculation Rules
|
||
|
||
Keep calculation logic centralized.
|
||
|
||
Do not spread electrical formulas across route handlers, UI components, or database repositories.
|
||
|
||
Use dedicated calculation services or pure functions.
|
||
|
||
Examples:
|
||
|
||
```text
|
||
src/domain/calculations/power-calculation.ts
|
||
src/domain/services/power-balance.service.ts
|
||
```
|
||
|
||
Typical calculation concepts:
|
||
|
||
- Installed power total = quantity × installed power per unit
|
||
- Demand power = installed power total × demand factor
|
||
- Current calculation depends on voltage, phase count, and power factor
|
||
|
||
When implementing formulas, add comments for the electrical meaning, especially where three-phase and single-phase calculations differ.
|
||
|
||
Always be careful with units.
|
||
|
||
Preferred base units:
|
||
|
||
- Power: kW
|
||
- Current: A
|
||
- Voltage: V
|
||
- Demand factor: decimal number from 0 to 1
|
||
|
||
If other units are added later, implement explicit conversion helpers.
|
||
|
||
## Database Guidelines
|
||
|
||
Use SQLite initially.
|
||
|
||
Keep schema clear and readable.
|
||
|
||
Avoid premature normalization. Normalize where it prevents real inconsistency, not just for theoretical purity.
|
||
|
||
Recommended core tables:
|
||
|
||
- projects
|
||
- power_balances
|
||
- distribution_boards
|
||
- consumers
|
||
- consumer_categories or system_types, if needed later
|
||
|
||
Use migrations. Do not manually modify the database schema without creating a migration.
|
||
|
||
Use repositories or database access modules. Do not place raw database queries directly in UI components or high-level route handlers.
|
||
|
||
## API Guidelines
|
||
|
||
Keep API routes resource-oriented.
|
||
|
||
Example routes:
|
||
|
||
```text
|
||
GET /api/projects
|
||
POST /api/projects
|
||
GET /api/projects/:projectId
|
||
PUT /api/projects/:projectId
|
||
DELETE /api/projects/:projectId
|
||
|
||
GET /api/projects/:projectId/power-balances
|
||
POST /api/projects/:projectId/power-balances
|
||
|
||
GET /api/power-balances/:powerBalanceId/consumers
|
||
POST /api/power-balances/:powerBalanceId/consumers
|
||
PUT /api/consumers/:consumerId
|
||
DELETE /api/consumers/:consumerId
|
||
```
|
||
|
||
Validate all incoming API data.
|
||
|
||
Use shared validation schemas if possible.
|
||
|
||
## UI Guidelines
|
||
|
||
The UI should be practical and data-entry friendly.
|
||
|
||
Prioritize:
|
||
|
||
- Tables for consumers
|
||
- Inline editing where useful
|
||
- Clear grouping by distribution board or area
|
||
- Totals at group and project level
|
||
- German UI labels
|
||
- Consistent units in column headers
|
||
- Minimal clicks for adding multiple consumers
|
||
|
||
Use German labels such as:
|
||
|
||
- Projekt
|
||
- Leistungsbilanz
|
||
- Verteilung
|
||
- Verbraucher
|
||
- Anzahl
|
||
- Leistung je Stück
|
||
- Installierte Leistung
|
||
- Gleichzeitigkeitsfaktor
|
||
- Berechnete Leistung
|
||
- Bemerkung
|
||
|
||
Code identifiers must remain English.
|
||
|
||
## Testing Guidelines
|
||
|
||
Add tests for calculation logic.
|
||
|
||
Calculation tests are more important than superficial UI tests.
|
||
|
||
At minimum, test:
|
||
|
||
- Total installed power calculation
|
||
- Demand power calculation
|
||
- Quantity handling
|
||
- Single-phase current calculation, if implemented
|
||
- Three-phase current calculation, if implemented
|
||
- Edge cases such as quantity 0, demand factor 0, and missing optional values
|
||
|
||
Do not change formulas without updating or adding tests.
|
||
|
||
## Docker and Development
|
||
|
||
The project should be runnable in a local development environment, including on Windows with Docker Desktop.
|
||
|
||
If Docker is used, provide:
|
||
|
||
- `Dockerfile`
|
||
- `docker-compose.yml`
|
||
- clear volume handling for SQLite database files
|
||
- documented development commands
|
||
|
||
Avoid configurations that only work on Linux unless explicitly documented.
|
||
|
||
## Documentation Expectations
|
||
|
||
Keep documentation short but useful.
|
||
|
||
Document:
|
||
|
||
- How to install dependencies
|
||
- How to start the dev server
|
||
- How to run migrations
|
||
- How to run tests
|
||
- Basic domain assumptions
|
||
- Important formulas
|
||
|
||
Prefer concise Markdown documentation.
|
||
|
||
## Development Progress Documentation
|
||
|
||
Document the current implementation status in dedicated Markdown files whenever regular status updates are requested.
|
||
|
||
- Keep status tracking explicit with `TODO`, `WIP`, and `DONE` sections.
|
||
- For each relevant module or feature area, document:
|
||
- what it does,
|
||
- how it works,
|
||
- which files/functions are involved,
|
||
- why important design choices were made,
|
||
- current limitations or open points.
|
||
- Break larger features into small sub-sections so someone new can read through and understand the flow.
|
||
- Update these Markdown status documents incrementally during implementation so progress can be tracked clearly over time.
|
||
- Prefer understandable, step-by-step explanations over overly brief summaries when needed for clarity.
|
||
## Coding Style
|
||
|
||
Write clear, explicit TypeScript.
|
||
|
||
Prefer readability over cleverness.
|
||
|
||
Avoid:
|
||
|
||
- unnecessary generic abstractions
|
||
- magic numbers
|
||
- hidden side effects
|
||
- large files with unrelated responsibilities
|
||
- mixing UI, database, and calculation logic
|
||
|
||
Use meaningful names even if they are longer.
|
||
|
||
## Safety and Data Integrity
|
||
|
||
Do not delete user data without explicit confirmation in the UI or API design.
|
||
|
||
Use soft-delete only if the project introduces audit or recovery requirements.
|
||
|
||
Validate numeric values carefully:
|
||
|
||
- quantity must not be negative
|
||
- demand factor should normally be between 0 and 1
|
||
- installed power must not be negative
|
||
- voltage must be positive
|
||
- phase count should be limited to valid values
|
||
|
||
## Agent Behavior
|
||
|
||
When modifying this repository:
|
||
|
||
1. Inspect the existing structure before adding new files.
|
||
2. Reuse existing patterns unless they are clearly wrong.
|
||
3. Keep changes small and focused.
|
||
4. Do not introduce large framework changes without explicit instruction.
|
||
5. Do not silently change the database technology.
|
||
6. Do not silently change the ORM.
|
||
7. Keep domain terms consistent.
|
||
8. Add or update tests when changing calculation logic.
|
||
9. Update this `AGENTS.md` if a new recurring project rule is established.
|
||
10. Prefer practical implementation over theoretical perfection.
|
||
|
||
## Out of Scope Unless Explicitly Requested
|
||
|
||
Do not implement the following unless explicitly requested:
|
||
|
||
- Multi-tenant user management
|
||
- Role-based permissions
|
||
- Cloud deployment
|
||
- PostgreSQL migration
|
||
- Realtime collaboration
|
||
- Complex report designer
|
||
- Full BIM integration
|
||
- GAEB integration
|
||
- Revit integration
|
||
- Authentication providers
|
||
- Enterprise audit logging
|
||
|
||
## Preferred First Milestone
|
||
|
||
The first useful milestone should be:
|
||
|
||
- Create a project
|
||
- Create one power balance
|
||
- Add distribution boards
|
||
- Add consumers with quantity
|
||
- Calculate installed power and demand power
|
||
- Show totals in the UI
|
||
- Persist data in SQLite
|
||
- Provide basic tests for calculation logic
|
||
|
||
Do not start with advanced reporting before the core data and calculation workflow works.
|
||
|
||
## Current UI Workflow Requirements
|
||
|
||
Implement and preserve the following navigation and workflow structure:
|
||
|
||
1. A dedicated project page that lists all projects and allows creating new projects.
|
||
2. On the same project page, users can configure global devices/consumers.
|
||
3. Inside a project, users first see all distribution boards and can open a selected board.
|
||
4. Circuit lists are edited in a dedicated view where up to 3 circuit lists can be opened in parallel.
|
||
5. Users must be able to copy circuit entries/consumers between the open circuit lists with minimal clicks.
|
||
6. In the circuit-list view, exactly 1 list is open by default. Users can add/remove list panels dynamically with a minimum of 1 and a maximum of 3 open lists.
|
||
|
||
When implementing frontend changes, keep this structure as the default interaction model unless the user explicitly requests a different UX.
|
||
|
||
## Language and Text Rules
|
||
|
||
Use proper German umlauts (ä, ö, ü, Ä, Ö, Ü, ß) in all new or changed German UI texts and documentation text, unless technical constraints explicitly prevent this.
|
||
|
||
## Responsiveness Rule
|
||
|
||
Frontend implementations must remain fully responsive by default across mobile, tablet, laptop, and wide desktop breakpoints.
|
||
Layouts with dynamic panel counts (for example 1-3 parallel circuit-list panels) must adapt so available horizontal space is used appropriately instead of leaving fixed empty columns.
|
||
|
||
## Language and Text Rules (Enforced)
|
||
|
||
Use proper German umlauts (�, �, �, �, �, �, �) in all new or changed German UI texts and documentation text, unless technical constraints explicitly prevent this.
|
||
|
||
|
||
## Project Voltage and Columns Rules
|
||
|
||
- Project properties must include default single-phase and three-phase voltages. Use 230 V for single-phase and 400 V for three-phase by default, and allow users to change both values in project settings.
|
||
- In circuit lists, when a consumer is single-phase and has no explicit voltage override, calculations use the project single-phase default voltage. When a consumer is three-phase and has no explicit voltage override, calculations use the project three-phase default voltage.
|
||
- When creating a new consumer/device entry, the standard input fields should be: consumer display name, quantity, unit power, demand factor, and total power.
|
||
- By default, the table should initially hide: power factor (cos phi), phase count, and current.
|
||
- Users must be able to add any available attribute as a table column at any time, and must be able to reorder column positions.
|
||
|
||
## Encoding Rule
|
||
|
||
- All text files must be saved as UTF-8.
|
||
- German UI text must never contain mojibake artifacts (for example geöffnet, wählen, Übernehmen, ←, →).
|
||
- If such artifacts appear, they must be corrected immediately before merge or handoff.
|